Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede2.usc.br:8080/jspui/handle/tede/128
Tipo do documento: Dissertação
Título: Análise da remodelação óssea peri-cervical em implantes unitários na região estética
Título(s) alternativo(s): Analysis of bone turnover in peri-implant unit in the cervical region aesthetic
Autor: Cosenza, Heitor Bernardes 
Primeiro orientador: Almeida, Juliano Milanezi de
Primeiro coorientador: Carvalho, Renato Savi de
Resumo: O objetivo do estudo foi avaliar a remodelação óssea pericervical comparando implantes usinados (Nobel Biocare Suécia) a implantes de superfície tratada TiUnite® (Nobel Biocare Suécia) na região estética. Para isto, foram selecionados dez pacientes que receberam implantes usinados e dez pacientes que receberam implantes TiUnite® e possuem entre quatro e seis anos de função. Radiografias neste período foram digitalizadas e o passo de rosca, medida fornecida pela indústria Nobel Biocare do Brasil, foi utilizado para calibrar o software ImageJ, ferramenta de medição de imagens digitais. Com isto, as distorções do processo de tomada radiográfica foram minimizadas.Três pontos foram determinados: ângulo formado pelo espelho do implante e sua parede axial; primeiro ponto de contato osso implante; crista óssea remanescente, respectivamente, A, B e C. Todos os implantes são unitários e possuiam dentes vizinhos tanto na mesial quanto na distal. As distâncias foram medidas três vezes para cada relação (AB, AC, BC) por apenas um examinador. Para verificar o erro do método foi utilizada a fórmula de Dahlberg e os resultados foram avaliados pelo teste t de student. Não houve diferenças estatisticamente significativas entre os dois grupos. Consequentemente, foi possível uní-los, o que resultou em uma média de remodelação óssea a partir do espelho do implante de 1,87mm entre quatro e seis anos de função.
Abstract: The aim of the study was to evaluate pericervical remodeling comparing machined surface implants (Nobel Biocare Sweeden) to TiUnite® surface implants (Nobel Biocare Sweeden) on aesthetic site. For this purpose, ten machined implant patients and ten TiUnite® implant patients, with between four and six years of function, were selected. Radiographs were scanned and the thread pitch, known measure provided by Nobel Biocare of Brazil, was used to calibrate ImageJ software, digital image measuring tool. Consequently, radiograph distortion was minimized. Three points were set: angle between implant mirror and long axis wall, first point of bone/implant contact, remnant bone crest, respectively, A, B and C. They were all single implants and had neiboring teeth, mesial and distal. Distances were taken by one examiner three times between each relation (AB, AC, BC). Dahlberg formula was used to verify the method error and the results were evaluated by Student t test. There were no statistically significant difference between two groups. Consequently, it was possible to put the groups together, what resulted in 1,87mm in average of bone pericervical remodelin, from the implant mirror to the first implant/bone contact, in a period between four and six years.
Palavras-chave: REMODELAÇÃO ÓSSEA PERI-CERVICAL
PERDA ÓSSEA MARGINAL
PERDA ÓSSEA PERIIMPLANTAR
SAUCERIZAÇÃO
ESTÉTICA
IMPLANTE UNITÁRIO
PERI-NECK BONE REMODELING
MARGINAL BONE LOSS, LOSS BONE PERIIMPLANTAR
SAUCERIZATION
AESTHETICS
IMPLANT UNIT
Área(s) do CNPq: CIENCIAS DA SAUDE::ODONTOLOGIA
Idioma: por
País: BR
Instituição: IASCJ - Universidade Sagrado Coração
Sigla da instituição: USC
Departamento: Ciências da Saúde e Biológicas
Programa: Implantologia
Citação: COSENZA, Heitor Bernardes. Analysis of bone turnover in peri-implant unit in the cervical region aesthetic. 2011. 36 f. Dissertação (Mestrado em Biologia Oral - Implantologia) - IASCJ - Universidade Sagrado Coração, Bauru, 2011.
Tipo de acesso: Acesso Aberto
URI: http://localhost:8080/tede/handle/tede/128
Data de defesa: 8-Fev-2011
Aparece nas coleções:Mestrado em Implantologia

Arquivos associados a este item:
Arquivo TamanhoFormato 
dissertacao_heitor_bernardes_cosenza.pdf1,46 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.