Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede2.usc.br:8080/jspui/handle/tede/131
Tipo do documento: Tese
Título: Novo protocolo para análise física tridimensional do desvio angular em cirurgia guiada na implantologia
Título(s) alternativo(s): New protocol for three-dimensional physical analysis of the angular deviation in guided surgery in implantology
Autor: Ferreira, Edilson Jose 
Primeiro orientador: Francischone, Carlos Eduardo
Resumo: O desvio angular na cirurgia guiada pode ser obtido pela interpolação de imagens em programas específicos. Entretanto, a mensuração em tempo real também pode ser obtida tridimensionalmente. O objetivo deste trabalho foi avaliar o desvio angular dos implantes na técnica de cirurgia guiada, utilizando os modelos de gesso como referência. Cinco pacientes foram selecionados. Após o planejamento reverso e a obtenção dos cortes tomográficos (Toshiba Xvision, 0,4 mm de espessura), utilizou-se o software Procera NobelGuide para posicionar os implantes virtualmente. Em seguida, os guias cirúrgicos obtidos e as réplicas dos implantes foram conectados para geração do modelo A. Foram colocados implantes Brånemark NobelSpeedy (4 mm diâmetro x 11,5 mm-18 mm de comprimento). Após as cirurgias, uma moldagem foi realizada ao nível das plataformas dos implantes para obtenção dos modelos B. Todas as próteses definitivas foram entregues até 12 horas depois. Uma máquina CMM (Tesa Micro-Hite 3D, Suíça) foi utilizada para mensurar a inclinação dos implantes nos planos X, Y e Z. O desvio angular (!Z, diferença entre os modelos A e B) para cada implante foi mensurado em graus, minutos e segundos. O desvio angular médio registrado foi de 0,82 ± 0,71 graus (faixa de 0-4,13 graus). Os valores obtidos estiveram dentro das médias descritas na literatura. Esse protocolo de mensuração tridimensional mostrou-se confiável e abre novas possibilidades de estudo.
Abstract: Implant angular deviation during guided surgery can be obtained by image interpolation on appropriate software. However, real time measurement can also be made on a 3-D way. The aim of this study was to evaluate the angular deviation using dental plaster casts as physical references. Five patients were enrolled. After reverse treatment planning, 0.4mm-thick slices were obtained by CT scanning. (Toshiba Xvision), using the Procera NobelGuide software for virtual implant positioning. Then, with the surgical guides, implant replicas were connected to generate plaster model A. On surgery, Brånemark NobelSpeedy implants (4 mmdiameter x 11.5 mm-18 mm-length) were placed. An impression was made at the platform levels to generate plaster model B. All defi nitive prostheses were delivered after 12 hours. A CCM (Tesa Micro-Hite 3D, Swiss) was used to measure implant angulation in X, Y and Z planes. The angular deviation (!Z, absolute difference between models A and B) for each implant was generated in degrees, minutes and seconds. Mean angular deviation registered for all implants was approximately 0.82 ± 0.71 degrees (range of 0-4.13 degrees). The obtained values were within reported numbers in the literature. This measurement protocol is reliable and brings about new study possibilities.
Palavras-chave: CIRURGIA GUIADA
DESVIO ANGULAR
MÁQUINA DE COORDENADAS TRIDIMENSIONAIS
IMPLANTES DENTÁRIOS
GUIDED SURGERY
ANGULAR DEVIATION
CMM DEVICE
DENTAL IMPLANTS
Área(s) do CNPq: CIENCIAS DA SAUDE::ODONTOLOGIA
Idioma: por
País: BR
Instituição: IASCJ - Universidade Sagrado Coração
Sigla da instituição: USC
Departamento: Ciências da Saúde e Biológicas
Programa: Implantologia
Citação: FERREIRA, Edilson Jose. New protocol for three-dimensional physical analysis of the angular deviation in guided surgery in implantology. 2011. 71 f. Tese (Doutorado em Biologia Oral - Implantologia) - IASCJ - Universidade Sagrado Coração, Bauru, 2011.
Tipo de acesso: Acesso Aberto
URI: http://localhost:8080/tede/handle/tede/131
Data de defesa: 10-Fev-2011
Aparece nas coleções:Doutorado em Implantologia

Arquivos associados a este item:
Arquivo TamanhoFormato 
tese_edilson_jose_ferreira.pdf2,94 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.