Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede2.usc.br:8080/jspui/handle/tede/80
Tipo do documento: Dissertação
Título: Análise tomográfica da medida do desvio angular e linear entre implantes osteointegráveis planejados e inseridos por meio de cirurgia guiada
Título(s) alternativo(s): Tomography analysis of extent of deviation angle between linear and implants osteointegráveis planned and inserted by means of guided surgery
Autor: Barros, Carlos Alberto Villaça de Souza 
Primeiro orientador: Rossetti, Paulo Henrique Orlato
Primeiro coorientador: Padovan, Luís Eduardo Marques
Resumo: A cirurgia guiada através de softwares em odontologia é uma realidade incontestável, apresentando vantagens no pós-operatório com comodidade para paciente e de previsibilidade para o implantodontista. A perfeição e a beleza da técnica de uma cirurgia sem retalho, pouquíssimo sangramento e a exatidão do posicionamento dos implantes, quando bem executada, torna a cirurgia limpa e rápida, o que leva aos neófitos em implantodontia a acreditar que qualquer pessoa, com um mínimo de treinamento, será capaz de realizar tal técnica com destreza e pouco esforço. É importante salientar que o único lugar que sucesso vem antes do trabalho é o dicionário, portanto, para aqueles de desejam se aventurar nesse desafio empolgante, sejam bem-vindos a uma jornada de estudos longa e detalhada, passando pelos ensinamentos de estética e biomecânica da prótese, os cuidados com assepsia e firmeza dos traços advindos da cirurgia e o conhecimento dos recursos técnicos dos softwares que fornecem informações e possibilitam testar diversas soluções praticáveis para cada caso até chegar a uma solução ideal. Diversas teorias deram embasamento para a cirurgia guiada alcançar atualmente o Estado de Arte em Odontologia. Este trabalho teve por objetivo verificar a precisão da técnica comparando os resultados dos implantes inseridos através de cirurgias guiadas por computador com os resultados conseguidos no ambiente 3D. Os resultados demonstraram que a técnica é segura e precisa para ser utilizada nos consultórios, com previsibilidade para o implantodontista e com mais conforto para o paciente.
Abstract: The surgery guided by software in dentistry presents advantages in the postoperative stage, with convenience for the patient and predictability to the implant dentist. The aim of this work was to verify the accuracy of the technique through the comparison of results of implants inserted by computer-guided surgery with the results achieved in the 3D environment. Guided surgeries were performed by the software Dental Slice (Bioparts - Brasília) and also using the System Neoguide (Neodent - Curitiba) at the University of the Sacred Heart (Universidade do Sagrado Coração), using 4 to 6 implants with a diameter of 3.5mm and 3.75mm. We evaluated the angular deviation and differences between the position of the head of the implant, middle and apical third of the implants which were planned in software and in the inserted implants. The results of the angular deviations obtained an average of 2.033 ± 0.782º, the difference in position on the head of the implant was 1.082 ± 0.907mm in the middle third of the difference was 1.599 ± 1.22mm at the apex of the implant and the difference found was 2.542 ± 2.047mm. The results showed that the technique is safe and accurate to be used in clinics.
Palavras-chave: CIRURGIA GUIADA
CIRURGIA SEM RETALHO
IMPLANTES OSSEOINTEGRÁVEIS
GUIDED SURGERY
FLAPLESS SURGERY, OSSEOINTEGRATED IMPLANTS
SOFTWARE
NEOGUIDE
DENTAL SLICE
Área(s) do CNPq: CIENCIAS DA SAUDE::ODONTOLOGIA
Idioma: por
País: BR
Instituição: IASCJ - Universidade Sagrado Coração
Sigla da instituição: USC
Departamento: Ciências da Saúde e Biológicas
Programa: Implantologia
Citação: BARROS, Carlos Alberto Villaça de Souza. Tomography analysis of extent of deviation angle between linear and implants osteointegráveis planned and inserted by means of guided surgery. 2010. 50 f. Dissertação (Mestrado em Ciências da Saúde e Biológicas) - IASCJ - Universidade Sagrado Coração, Bauru, 2010.
Tipo de acesso: Acesso Aberto
URI: http://tede2.usc.br:8080/tede/handle/tede/80
Data de defesa: 3-Mai-2010
Aparece nas coleções:Mestrado em Implantologia

Arquivos associados a este item:
Arquivo TamanhoFormato 
dissertacao_carlos_alberto_villaca_de_souza_barros.pdf6,46 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.